Dear all, I am packaging `downtimed`, a daemon for the recording of system downtimes. Taking its purpose into account the obvious start and stop runlevels are:
Default-Start : S Default-Stop : 0 6 since the daemon should be running as long as ever possible. However, update-rc.d disagrees vividly with me (and possibly also insserv), since it prefers to call aloud update-rc.d: warning: downtimed start runlevel arguments (2 3 4 5) do not match LSB Default-Start values (S) update-rc.d: warning: downtimed stop runlevel arguments (0 1 6) do not match LSB Default-Stop values (0 6) Am I in error, or is there a proper way of silencing these warning messages? Best regards, Mats Erik Andersson, DM -- To UNSUBSCRIBE, email to debian-mentors-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org Archive: http://lists.debian.org/20110126222650.ga26...@mea.homelinux.org