Hi Philip,

Philip Ashmore wrote:

> Just as a last check after upgrading to 3.2.4-1 and
> hibernating/resuming, I ran "sensors"
> from the lm-sensors package.
> It reported this:
[...]
>   temp1:        +55.0°C  (crit = +100.0°C)
[...]
> I rebooted and "sensors" reported:
[...]
>    temp1:        +71.0°C  (crit = +100.0°C)
[...]
> Does this help or should I still report it upstream?

It helps (it's a nice and concrete symptom), which is why we should
get this information and an acpidump upstream[*] to avoid wasted
effort from them having to discover the same things independently.

Thanks,
Jonathan

[*] http://bugzilla.kernel.org product ACPI component Power-Thermal



--
To UNSUBSCRIBE, email to debian-kernel-requ...@lists.debian.org
with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org
Archive: http://lists.debian.org/20120218064817.GA3879@burratino