Craig wrote:
> 
> Hi guys
> 
> I am getting the following error message from cron
> 
> Does anyone know what steps I need to take to resync these 
> broken mirrors ?
> 
> And what the U stands for ?
> 
> [...]
> Personalities : [raid1]
> read_ahead 1024 sectors
> md2 : active raid1 ide/host0/bus0/target0/lun0/part4[0]
>       55552704 blocks [2/1] [U_]
> 
> md1 : active raid1 ide/host0/bus0/target0/lun0/part3[0]
>       1951808 blocks [2/1] [U_]
> 
> md0 : active raid1 ide/host0/bus0/target0/lun0/part2[1]
> ide/host0/bus0/target1/lun0/part2[0](F)
>       979840 blocks [2/1] [_U]
> 
U means "up", so this output says your second disk has failed
(ide/host0/bus0/target1/lun0/part2[0](F)).

Repair should start autmatically after next reboot (if the disk works).
Otherwise get another disk, same partitioning as the first disk, reboot and
the reconstruction should start.

Thomas


Reply via email to