Package: sensord
Version: 1:3.1.2-2
Severity: normal
Upgrading lm-sensors package from 3.1.0-2 to 3.1.2-2 breaks
load average monitoring.
$ cat /etc/default/sensord
ALARM_INTERVAL=1m
LOG_INTERVAL=12h
SYSLOG_FACILITY=daemon
RRD_FILE=/var/sensors/mymachine.rrd
RRD_INTERVAL=5m
RRD_LOADAVG=yes
/etc/init.d/sensord does contain '-a' for monitoring load:
if [ -n "$RRD_LOADAVG" ]; then RRD_LOADAVG="-a"; fi
which gives a ps listing of:
/usr/sbin/sensord -i 1m -l 12h -f daemon -t 5m -r /var/sensors/mymachine.rrd -a
# /etc/init.d/sensord restart
$ rrdtool dump /var/sensors/mymachine.rrd | grep -i loadavg
returns nothing.
The same on 3.1.0-2 gives
$ rrdtool dump /var/sensors/sm12.rrd|grep load
<name> loadavg </name>
In both cases, /var/sensors/mymachine.rrdcgi contains a reference to
load average:
<RRD::GRAPH /var/sensors/daily-temperature.png
...
LINE2:loadavg#7cfcce:"Load Average">
-- System Information:
Debian Release: lenny/sid
APT prefers unstable
APT policy: (500, 'unstable')
Architecture: amd64 (x86_64)
Kernel: Linux 2.6.26-2-amd64 (SMP w/2 CPU cores)
Locale: LANG=en_US, LC_CTYPE=en_US (charmap=ISO-8859-1)
Shell: /bin/sh linked to /bin/bash
Versions of packages sensord depends on:
ii libc6 2.7-12 GNU C Library: Shared libraries
ii librrd4 1.4.3-1 time-series data storage and displ
ii libsensors4 1:3.1.2-2 library to read temperature/voltag
ii lm-sensors 1:3.1.2-2 utilities to read temperature/volt
sensord recommends no packages.
-- no debconf information
--