On Sat, Jul 04, 2009 at 08:29:49PM -0600, thomas morgan wrote: > Package: collectd > Version: 4.6.3-1~bpo50+1 […] > There is some kind of incompatibility between collectd and powerdns > 2.9.22. With powerdns support enabled in collectd, collectd connects > to powerdns's unix socket. The connection hangs indefinitely. […] > collectd will no longer even shutdown and must be kill -9'd. It render > powerdns's control socket useless as well, so it can no longer be > managed either (until collectd is killed). > > Things work as expected with powerdns 2.9.21.2. I tried collectd 4.6.2 > also, with the same problem.
The two connection types, “Server” and “Recursor”, actually result in different types of sockets. With “Server” the UNIX socket is used in STREAM mode (think: TCP). In this mode, the plugin will issue the SHOW * command to the PowerDNS plugin and then read back all the data the server is sending back. The appropriate function returns when the server (PowerDNS) closes the connection. I'd check if this is the case. Maybe the PowerDNS folks decided that it'd be a nice feature to be able to send (and receive) multiple consecutive requests (/ answers) via the same connection. If that is the case, it'd be useful to know how to recognize the end of a transmission. Regards, -octo P. S.: Kudos to Luke for his patch, I've applied it to the bugfix branches of the source repository. -- Florian octo Forster Hacker in training GnuPG: 0x91523C3D http://verplant.org/
signature.asc