On Thu, Jul 24, 2008 at 03:20:07PM -0400, Guido Günther wrote: Hi,
> > However kvm is started with no -serial option... Moreover <console> > > sections > > seem to be ignored as well and -monitor is always set to pty, but my created > > instances don't have any <console> associated to it in the result xml dump, > > and > > virsh console doesn't work... > Could you attche the full xml? I believe this is still part of the upgrade problem before... :) On the other hand, I've been able to connect serial devices to ptys... If I wanted to do it on unix sockets, is there a way to specify a listening socket, rather than an already connected one? (options server,nowait to kvm/qemu) :) Thanks, Guido -- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]