Giuseppe Sacco wrote:
Il giorno ven, 25/08/2006 alle 12.24 +0200, Thomas Schorpp ha scritto:
Giuseppe Sacco wrote:
Package: hylafax-server
Version: 1:4.2.1-5sarge3
Severity: grave
Tags: security
Justification: renders package unusable
Some line modems misinterpret human voice as V.9x, etc, connection
requests. This makes the server spawn getty-link with attach to the
line modem device which locks the device 4E4 even after OnHook.
What is your getty program pointed by getty-link?
shell
I think this is a wrong configuration. The link should point to a getty
program and GettArgs should be non zero in order to have faxgetty call
getty when answering a data call.
maybe, but then a working default config must be delivered to supress
the issue.
You have two options:
1. if you do not want the have getty called on data calls, just set a
blank value for GettyArgs in /etc/hylafax/config.ttyS? . Then restart
hylafax.
2. if you want to receive data calls and have getty handle it, make the
getty-link point to a real getty program, such as mgetty or the
standard /sbin/getty from util-linux package.
Please correct your configuration and write to me if it works.
1.: yes, works as expected, works around the issue at least for 10 tests.
correct what? it has been the package's and hylafax setup tools *default* config.
this cannot resolve this bug.
Bye,
Giuseppe Sacco
y
tom
--