Package: sane Version: 1.0.14-16 Severity: grave Tags: upstream Justification: renders package unusable X-Debbugs-Cc: compte.perso.de-al...@bbox.fr
last week-end tried to scan a very important document . no more xsane , simple-scan , hp-scan or vuescan works . alain@sid:~$ hp-scan HP Linux Imaging and Printing System (ver. 3.21.2) Scan Utility ver. 2.2 Copyright (c) 2001-18 HP Development Company, LP This software comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to distribute it under certain conditions. See COPYING file for more details. ----------------- | SELECT DEVICE | ----------------- Num Scan device URI -------- ------------------------------------------------- 0 escl:http://127.0.0.1:60000 1* hpaio:/usb/ENVY_5530_series?serial=CN595530XD06BX Enter number 0...1 for device (q=quit, <enter>=default: 1*) ? warning: No destinations specified. Adding 'file' destination by default. Using device hpaio:/usb/ENVY_5530_series?serial=CN595530XD06BX Opening connection to device... error: SANE: Error during device I/O (code=9) alain@sid:~$ hp-scan HP Linux Imaging and Printing System (ver. 3.21.2) Scan Utility ver. 2.2 Copyright (c) 2001-18 HP Development Company, LP This software comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to distribute it under certain conditions. See COPYING file for more details. ----------------- | SELECT DEVICE | ----------------- Num Scan device URI -------- ------------------------------------------------- 0 escl:http://127.0.0.1:60000 1* hpaio:/usb/ENVY_5530_series?serial=CN595530XD06BX Enter number 0...1 for device (q=quit, <enter>=default: 1*) ?0 warning: No destinations specified. Adding 'file' destination by default. Using device escl:http://127.0.0.1:60000 Opening connection to device... error: SANE: Out of memory (code=10) alain@sid:~$ systemctl list-units "ipp-usb*" | grep service ipp-usb.service loaded active running Daemon for IPP over USB printer support alain@sid:~$ scanimage -L device `escl:http://127.0.0.1:60000' is a HP ENVY 5530 series [FE04D6] (USB) flatbed scanner device `hpaio:/usb/ENVY_5530_series?serial=CN595530XD06BX' is a Hewlett-Packard ENVY_5530_series all-in-one your command : simple-scan escl:http://127.0.0.1:60000 was nearly ok . simple-scan started to connect and , quickly , closed itself : "cannot connect" alain@sid:~$ lsusb -v | grep -A 3 bInterfaceClass.*7 Couldn't open device, some information will be missing Couldn't open device, some information will be missing Couldn't open device, some information will be missing bInterfaceClass 7 Printer bInterfaceSubClass 1 Printer bInterfaceProtocol 4 iInterface 0 -- bInterfaceClass 7 Printer bInterfaceSubClass 1 Printer bInterfaceProtocol 2 Bidirectional iInterface 0 -- bInterfaceClass 7 Printer bInterfaceSubClass 1 Printer bInterfaceProtocol 4 iInterface 0 can't get debug descriptor: Resource temporarily unavailable Couldn't open device, some information will be missing -- bInterfaceClass 7 Printer bInterfaceSubClass 1 Printer bInterfaceProtocol 4 iInterface 0 Couldn't open device, some information will be missing Couldn't open device, some information will be missing Couldn't open device, some information will be missing Couldn't open device, some information will be missing Couldn't open device, some information will be missing Couldn't open device, some information will be missing That is a possible upstream bug in SANE for this device. alain@sid:~$ sudo apt install --reinstall sane-airscan [sudo] Mot de passe de alain : Lecture des listes de paquets... Fait Construction de l'arbre des dépendances... Fait Lecture des informations d'état... Fait 0 mis à jour, 0 nouvellement installés, 1 réinstallés, 0 à enlever et 9 non mis à jour. Il est nécessaire de prendre 117 ko dans les archives. Après cette opération, 0 o d'espace disque supplémentaires seront utilisés. Réception de :1 http://deb.debian.org/debian testing/main amd64 sane-airscan amd64 0.99.24-1 [117 kB] 117 ko réceptionnés en 0s (1 268 ko/s) (Lecture de la base de données... 283524 fichiers et répertoires déjà installés.) Préparation du dépaquetage de .../sane-airscan_0.99.24-1_amd64.deb ... Dépaquetage de sane-airscan (0.99.24-1) sur (0.99.24-1) ... Paramétrage de sane-airscan (0.99.24-1) ... Traitement des actions différées (« triggers ») pour man-db (2.9.4-2) ... alain@sid:~$ scanimage -L device `escl:http://127.0.0.1:60000' is a HP ENVY 5530 series [FE04D6] (USB) flatbed scanner device `airscan:e0:HP ENVY 5530 series [FE04D6] (USB)' is a eSCL HP ENVY 5530 series [FE04D6] (USB) ip=127.0.0.1 device `hpaio:/usb/ENVY_5530_series?serial=CN595530XD06BX' is a Hewlett-Packard ENVY_5530_series all-in-one still understood nothing . is that what you wanted ? do i have to open a "sane" bug ? thanks to Brian Potkin . -- System Information: Debian Release: bullseye/sid APT prefers unstable APT policy: (500, 'unstable'), (100, 'testing'), (100, 'stable'), (1, 'experimental') Architecture: amd64 (x86_64) Foreign Architectures: i386 Kernel: Linux 5.10.0-3-amd64 (SMP w/16 CPU threads) Kernel taint flags: TAINT_OOT_MODULE, TAINT_UNSIGNED_MODULE Locale: LANG=fr_FR.UTF-8, LC_CTYPE=fr_FR.UTF-8 (charmap=UTF-8), LANGUAGE not set Shell: /bin/sh linked to /usr/bin/dash Init: systemd (via /run/systemd/system) LSM: AppArmor: enabled Versions of packages sane depends on: ii libc6 2.31-9 ii libgimp2.0 2.10.22-2 ii libglib2.0-0 2.66.7-1 ii libgtk2.0-0 2.24.33-1 ii libsane1 [libsane] 1.0.31-4 sane recommends no packages. Versions of packages sane suggests: ii gimp 2.10.22-2