Package: laptop-mode-tools
Version: 1.23-1
Severity: normal
Hi!
Looking at line 605:
if (($REMAINING * 60 / $PRESENT_RATE >= $MINIMUM_BATTERY_MINUTES)) ; then
ENOUGH_CHARGE=0
fi
This just looks *wrong* to me. It makes dataloss sensitive features
disabled, though my batteries are fully charged. It should probably be
ENOUGH_CHARGE=1
/Mikael