Op 11-05-2007 om 22:25 schreef Geert Stappers:
> Op 11-05-2007 om 14:26 schreef Rolf Brudeseth:
> 
> > Note that there are three possible consoles on an IBM p5 Server:
> > co:2345:respawn:/sbin/getty hvsi0 9600 vt100   <== Console via serial port 
> > 1 (Non-HMC managed)
> > co:2345:respawn:/sbin/getty hvsi1 9600 vt100   <== Console via serial port 
> > 2 (Non-HMC managed)
> > co:2345:respawn:/sbin/getty hvc0 9600 vt100    <== Console via HMC
> 
> Would it OK to activate all three?
> Assuming that detecting a p5 server can be done.

Bugreport #394970 is/was about serial ports on a p5 server.
In that report is not yet a succesfull test confirmed.


HtH
GSt


-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]

Reply via email to