stchu wrote:
But when the web-ui shows the node dead, -report still shows "in service"
and the living nodes=3 (in web-ui: living=2 dead=1).
please file a jira and describe how to reproduce in as much detail as
you can in a comment.
thanks,
Raghu.
stchu
2009/3/26 Raghu Angadi <rang...@yahoo-inc.com>
stchu wrote:
Hi,
I do a test about the datanode crash. I stop the networking on one of the
datanode.
The Web app and fsck report that datanode dead after 10 mins. But dfsadmin
-report
are not report that over 25 mins. Is this correct?
Nope. Both web-ui and '-report' from the same source of info. They should
be consistent.
Raghu.
Thanks for your guide.
stchu