zhangshenghang opened a new pull request, #12786:
URL: https://github.com/apache/seatunnel/pull/12786

   ### Purpose of this pull request
   
   The Tablestore sink fails with a `ClassCastException` on the first row for 
most numeric column types. `DefaultSeaTunnelRowSerializer` converts row values 
with direct casts that do not match the Java types SeaTunnel actually puts in 
the row:
   
   ```java
   // convertColumn, INTEGER case — reached for INT, TINYINT, SMALLINT, BIGINT 
columns
   ColumnValue.fromLong((long) value);        // (long) on Object compiles to 
checkcast Long
   
   // convertColumn, DOUBLE case — reached for FLOAT, DOUBLE, DECIMAL columns
   ColumnValue.fromDouble((Double) value);    // checkcast Double
   
   // convertPrimaryKeyColumn, INTEGER case — reached for integer primary keys
   PrimaryKeyValue.fromLong((long) value);
   ```
   
   SeaTunnel rows carry `Integer`/`Byte`/`Short` for INT/TINYINT/SMALLINT and 
`Float`/`BigDecimal` for FLOAT/DECIMAL, and a `checkcast` to `Long`/`Double` 
rejects those types, so:
   
   - any table with an `int`, `tinyint`, or `smallint` column → 
`ClassCastException: class java.lang.Integer cannot be cast to class 
java.lang.Long` on the first row;
   - any table with a `float` or `decimal` column → `ClassCastException` 
(`Float`/`BigDecimal` cannot be cast to `Double`);
   - an `int` primary key fails the same way.
   
   Only `bigint` and `double` columns ever worked, although `convertColumnType` 
explicitly maps INT/TINYINT/SMALLINT → INTEGER and FLOAT/DECIMAL → DOUBLE (i.e. 
these types are supposed to be supported).
   
   The fix converts through `Number` (`((Number) value).longValue()` / 
`.doubleValue()`), which handles `Byte`, `Short`, `Integer`, `Long`, `Float`, 
`Double` and `BigDecimal` uniformly.
   
   ### Does this PR introduce _any_ user-facing change?
   
   No API/config change. Behaviour change: tables containing 
`int`/`tinyint`/`smallint`/`float`/`decimal` columns (or integer primary keys) 
can now be written instead of failing with `ClassCastException` on the first 
row.
   
   ### How was this patch tested?
   
   Added `DefaultSeaTunnelRowSerializerTest`: integer-family columns 
(`tinyint`/`smallint`/`int`/`bigint`), floating-point columns 
(`float`/`double`/`decimal`), an `int` primary key, plus string/boolean/binary 
baseline cases and the configured table name. Verified against the pre-fix code 
that the integer/floating-point/primary-key tests fail with exactly the 
reported `ClassCastException`s and pass after the fix. Full module suite 
passes: `connector-tablestore` — 14 tests, 0 failures. `spotless:check` passes.


-- 