--- Begin Message ---
Hi Lee,
This can be done, the chassis will go into an alarm state due to the
incompatible fan versions, however it is cosmetic and as soon as you replace
the second tray with v2, the alarms will clear. Example logs;
%PLATFORM-ENVMON-4-FANTRAY_VER_MISMATCH : Fan tray version mismatch warning on
slot 0/FT0/SP
%PLATFORM-ENVMON-2-ENV_CONDITION : Outstanding environmental condition exists
in the chassis
%PLATFORM-ENVMON-4-FANTRAY_VER_MISMATCH_CLEAR : Fan tray version mismatch
warning cleared on slot 0/FT0/SP
%PLATFORM-ENVMON-2-ENV_CONDITION : Outstanding environmental condition cleared
in the chassis
Perrin
On 29 Jun 2021, at 8:13 am, Lee Starnes <[email protected]> wrote:
Hello everyone,
I have some ASK9010 chassis that are getting upgraded fan trays from v1 to
v2. My question is to upgrade these, is it possible to pull one and replace
it and then pull the other and replace or will the system have issues with
mixed fan trays during that short period?
If it can't be swapped 1 at a time, will the chassis need to shutdown to
swap both or will the chassis continue to run for the 30 - 60 seconds it
takes to swap the new ones in?
Best,
-Lee
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/