Changeset: bbf8b875fae7 for MonetDB
URL: http://dev.monetdb.org/hg/MonetDB?cmd=changeset;node=bbf8b875fae7
Modified Files:
        sql/test/emptydb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
        sql/test/emptydb-upgrade-chain/Tests/upgrade.stable.out
        sql/test/emptydb-upgrade-hge/Tests/upgrade.stable.out.int128
        sql/test/emptydb-upgrade/Tests/upgrade.stable.out
        sql/test/testdb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
        sql/test/testdb-upgrade-chain/Tests/upgrade.stable.out
        sql/test/testdb-upgrade-hge/Tests/upgrade.stable.out.int128
        sql/test/testdb-upgrade/Tests/upgrade.stable.out
Branch: Dec2016
Log Message:

Approve upgrade output after release of Dec2016-SP2.


diffs (120 lines):

diff --git a/sql/test/emptydb-upgrade-chain-hge/Tests/upgrade.stable.out.int128 
b/sql/test/emptydb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
--- a/sql/test/emptydb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
+++ b/sql/test/emptydb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
@@ -24,11 +24,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/R   module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 38 where sqlname = 'decimal' and digits = 39;
-update sys.args set type_digits = 38 where type = 'decimal' and type_digits = 
39;
-set schema "sys";
 
 # 15:26:18 >  
 # 15:26:18 >  "mclient" "-lsql" "-ftest" "-Eutf-8" "-i" "-e" 
"--host=/var/tmp/mtest-21187" "--port=38946"
diff --git a/sql/test/emptydb-upgrade-chain/Tests/upgrade.stable.out 
b/sql/test/emptydb-upgrade-chain/Tests/upgrade.stable.out
--- a/sql/test/emptydb-upgrade-chain/Tests/upgrade.stable.out
+++ b/sql/test/emptydb-upgrade-chain/Tests/upgrade.stable.out
@@ -24,11 +24,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/R   module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 18 where sqlname = 'decimal' and digits = 19;
-update sys.args set type_digits = 18 where type = 'decimal' and type_digits = 
19;
-set schema "sys";
 
 # 15:41:19 >  
 # 15:41:19 >  "mclient" "-lsql" "-ftest" "-Eutf-8" "-i" "-e" 
"--host=/var/tmp/mtest-7576" "--port=32696"
diff --git a/sql/test/emptydb-upgrade-hge/Tests/upgrade.stable.out.int128 
b/sql/test/emptydb-upgrade-hge/Tests/upgrade.stable.out.int128
--- a/sql/test/emptydb-upgrade-hge/Tests/upgrade.stable.out.int128
+++ b/sql/test/emptydb-upgrade-hge/Tests/upgrade.stable.out.int128
@@ -24,11 +24,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/R   module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 38 where sqlname = 'decimal' and digits = 39;
-update sys.args set type_digits = 38 where type = 'decimal' and type_digits = 
39;
-set schema "sys";
 
 # 15:26:18 >  
 # 15:26:18 >  "mclient" "-lsql" "-ftest" "-Eutf-8" "-i" "-e" 
"--host=/var/tmp/mtest-21187" "--port=38946"
diff --git a/sql/test/emptydb-upgrade/Tests/upgrade.stable.out 
b/sql/test/emptydb-upgrade/Tests/upgrade.stable.out
--- a/sql/test/emptydb-upgrade/Tests/upgrade.stable.out
+++ b/sql/test/emptydb-upgrade/Tests/upgrade.stable.out
@@ -24,11 +24,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/R   module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 18 where sqlname = 'decimal' and digits = 19;
-update sys.args set type_digits = 18 where type = 'decimal' and type_digits = 
19;
-set schema "sys";
 
 # 15:41:18 >  
 # 15:41:18 >  "mclient" "-lsql" "-ftest" "-Eutf-8" "-i" "-e" 
"--host=/var/tmp/mtest-7576" "--port=32696"
diff --git a/sql/test/testdb-upgrade-chain-hge/Tests/upgrade.stable.out.int128 
b/sql/test/testdb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
--- a/sql/test/testdb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
+++ b/sql/test/testdb-upgrade-chain-hge/Tests/upgrade.stable.out.int128
@@ -22,11 +22,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/R   module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 38 where sqlname = 'decimal' and digits = 39;
-update sys.args set type_digits = 38 where type = 'decimal' and type_digits = 
39;
-set schema "testschema";
 
 # 15:26:22 >  
 # 15:26:22 >  "/usr/bin/python2" "upgrade.SQL.py" "upgrade"
diff --git a/sql/test/testdb-upgrade-chain/Tests/upgrade.stable.out 
b/sql/test/testdb-upgrade-chain/Tests/upgrade.stable.out
--- a/sql/test/testdb-upgrade-chain/Tests/upgrade.stable.out
+++ b/sql/test/testdb-upgrade-chain/Tests/upgrade.stable.out
@@ -19,11 +19,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/SQL module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 18 where sqlname = 'decimal' and digits = 19;
-update sys.args set type_digits = 18 where type = 'decimal' and type_digits = 
19;
-set schema "testschema";
 
 # 16:00:57 >  
 # 16:00:57 >  "/usr/bin/python2" "upgrade.SQL.py" "upgrade"
diff --git a/sql/test/testdb-upgrade-hge/Tests/upgrade.stable.out.int128 
b/sql/test/testdb-upgrade-hge/Tests/upgrade.stable.out.int128
--- a/sql/test/testdb-upgrade-hge/Tests/upgrade.stable.out.int128
+++ b/sql/test/testdb-upgrade-hge/Tests/upgrade.stable.out.int128
@@ -24,11 +24,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/R   module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 38 where sqlname = 'decimal' and digits = 39;
-update sys.args set type_digits = 38 where type = 'decimal' and type_digits = 
39;
-set schema "testschema";
 
 # 15:26:24 >  
 # 15:26:24 >  "/usr/bin/python2" "upgrade.SQL.py" "upgrade"
diff --git a/sql/test/testdb-upgrade/Tests/upgrade.stable.out 
b/sql/test/testdb-upgrade/Tests/upgrade.stable.out
--- a/sql/test/testdb-upgrade/Tests/upgrade.stable.out
+++ b/sql/test/testdb-upgrade/Tests/upgrade.stable.out
@@ -19,11 +19,6 @@ stdout of test 'upgrade` in directory 's
 # MonetDB/SQL module loaded
 
 Ready.
-Running database upgrade commands:
-set schema "sys";
-update sys.types set digits = 18 where sqlname = 'decimal' and digits = 19;
-update sys.args set type_digits = 18 where type = 'decimal' and type_digits = 
19;
-set schema "testschema";
 
 # 16:00:56 >  
 # 16:00:56 >  "/usr/bin/python2" "upgrade.SQL.py" "upgrade"
_______________________________________________
checkin-list mailing list
checkin-list@monetdb.org
https://www.monetdb.org/mailman/listinfo/checkin-list