It works , after I remove v2 address in ceph.conf.
Hope I see. Thank you !
[root@ceph-node1 ceph]# ceph -s
cluster:
id: e384e8e6-94d5-4812-bfbb-d1b0468bdef5
health: HEALTH_WARN
1 MDSs report slow metadata IOs
noout,nobackfill,norecover flag(s) set
9 osds down
no active mgr
Reduced data availability: 102 pgs
inactive, 128 pgs down, 8 pgs stale
Degraded data redundancy:
3664/29810955 objects degraded (0.012%), 28 pgs degraded, 29 pgs undersized
1 monitors have not enabled msgr2
services:
mon: 1 daemons, quorum ceph-node1 (age 13h)
mgr: no daemons active (since 3d)
mds: cephfs:1 {0=ceph-node1=up:active(laggy or crashed)}
osd: 12 osds: 3 up (since 3d), 12 in (since 3d)
flags noout,nobackfill,norecover
rgw: 1 daemon active (ceph-node1.rgw0)
data:
pools: 6 pools, 168 pgs
objects: 2.49M objects, 9.3 TiB
usage: 14 TiB used, 74 TiB / 88 TiB avail
pgs: 97.024% pgs not active
3664/29810955 objects degraded
(0.012%)
128 down
13
stale+undersized+degraded+peered
11
undersized+degraded+peered
6
stale+undersized+peered
5 undersized+peered
4
active+undersized+degraded
1 active+undersized
------------------ ???????? ------------------
??????: "Stefan Kooman"<ste...@bit.nl>;
????????: 2019??12??11??(??????) ????9:45
??????: "Chu"<o...@qq.com>;
????: "ceph-users"<ceph-users@lists.ceph.com>;
????: Re: //??[ceph-users] // ceph-mon is blocked after shutting down
and ip address changed
Quoting Cc?? (o...@qq.com):
> Hi,daemon is running when using admin socket
> [root@ceph-node1 ceph]#&nbsp; ceph --admin-daemon
/var/run/ceph/ceph-mon.ceph-node1.asok mon_status
> {
> &nbsp; &nbsp; "name": "ceph-node1",
> &nbsp; &nbsp; "rank": 0,
> &nbsp; &nbsp; "state": "leader",
> &nbsp; &nbsp; "election_epoch": 63,
> &nbsp; &nbsp; "quorum": [
> &nbsp; &nbsp; &nbsp; &nbsp; 0
> &nbsp; &nbsp; ],
> &nbsp; &nbsp; "quorum_age": 40839,
Your ceph.conf show that messenger should listen on 3300 (v2) and 6789
(v1). If only 6789 is actually listening ... and the client tries to
connect to 3300 ... you might get a timeout as well. Not sure if
messenger falls back to v1.
What happens when you change ceph.conf (first without restarting the
mon) and try a "ceph -s" again with a ceph client on the monitor node?
Gr. Stefan
--
| BIT BV https://www.bit.nl/
Kamer van Koophandel 09090351
| GPG:
0xD14839C6
+31 318 648 688 / i...@bit.nl
_______________________________________________
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com