You already have a thread talking about benchmarking the addition of WAL
and DB partitions to an OSD.  Why are you creating a new one about the
exact same thing?  As with everything, the performance increase isn't even
solely answerable by which drives you have, there are a lot of factors that
could introduce a bottleneck in your cluster.  But again, why create a new
thread for the exact same topic?

On Wed, Sep 12, 2018 at 12:06 PM Marc Roos <m.r...@f1-outsourcing.eu> wrote:

>
> When having a hdd bluestore osd with collocated wal and db.
>
>
> - What performance increase can be expected if one would move the wal to
> an ssd?
>
> - What performance increase can be expected if one would move the db to
> an ssd?
>
> - Would the performance be a lot if you have a very slow hdd (and thus
> not so much when you have a very fast hdd (sas 15k))
>
> - It would be best to move the wal first to the ssd, and then maybe also
> the db?
>
> In this CERN video (https://youtu.be/OopRMUYiY5E?t=931) of 2015 they are
> talking about 5-10x increase etc. But that is filestore of course.
>
>
>
>
>
>
>
> _______________________________________________
> ceph-users mailing list
> ceph-users@lists.ceph.com
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
>
_______________________________________________
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to