> On 12 Dec 2016, at 07:59, Wido den Hollander <w...@42on.com> wrote:
> 
> As David already said, when all OSDs are up and in for a PG Ceph will wait 
> for ALL OSDs to Ack the write. Writes in RADOS are always synchronous.

Apologies, I missed that.

Clearly I’ve been misunderstanding min_size for a while then: thanks for 
clearing it up. For most use size=3 cases it seems sensible to set it at 2 
rather than 1.

Oliver.
_______________________________________________
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to