<< Ceph performance in general (without read_ahead_kb) will be lower specially in all flash as the requests will be serialized within a PG
I meant to say Ceph sequential performance..Sorry for the spam.. From: ceph-users [mailto:ceph-users-boun...@lists.ceph.com] On Behalf Of Somnath Roy Sent: Tuesday, July 26, 2016 5:08 PM To: EP Komarla; ceph-users@lists.ceph.com Subject: Re: [ceph-users] Ceph performance pattern Not exactly, but, we are seeing some drop with 256K compare to 64K. This is with random reads though in Ubuntu. We had to bump up read_ahead_kb from default 128KB to 512KB to work around that. But, in RHEL we saw all sorts of issues with read_ahead_kb for small block random reads and I think it is already default to 4MB or so..If so, try to reduce it to 512KB and see.. Generally, for sequential reads, you need to play with read_ahead_kb to achieve better performance. Ceph performance in general (without read_ahead_kb) will be lower specially in all flash as the requests will be serialized within a PG. Our test is with all flash though and take my comments with a grain of salt in case of ceph + HDD.. Thanks & Regards Somnath From: EP Komarla [mailto:ep.koma...@flextronics.com] Sent: Tuesday, July 26, 2016 4:50 PM To: Somnath Roy; ceph-users@lists.ceph.com<mailto:ceph-users@lists.ceph.com> Subject: RE: Ceph performance pattern Thanks Somnath. I am running with CentOS7.2. Have you seen this pattern before? - epk From: Somnath Roy [mailto:somnath....@sandisk.com] Sent: Tuesday, July 26, 2016 4:44 PM To: EP Komarla <ep.koma...@flextronics.com<mailto:ep.koma...@flextronics.com>>; ceph-users@lists.ceph.com<mailto:ceph-users@lists.ceph.com> Subject: RE: Ceph performance pattern Which OS/kernel you are running with ? Try setting bigger read_ahead_kb for sequential runs. Thanks & Regards Somnath From: ceph-users [mailto:ceph-users-boun...@lists.ceph.com] On Behalf Of EP Komarla Sent: Tuesday, July 26, 2016 4:38 PM To: ceph-users@lists.ceph.com<mailto:ceph-users@lists.ceph.com> Subject: [ceph-users] Ceph performance pattern Hi, I am showing below fio results for Sequential Read on my Ceph cluster. I am trying to understand this pattern: - why there is a dip in the performance for block sizes 32k-256k? - is this an expected performance graph? - have you seen this kind of pattern before [cid:image001.png@01D1E760.729A3340] My cluster details: Ceph: Hammer release Cluster: 6 nodes (dual Intel sockets) each with 20 OSDs and 4 SSDs (5 OSD journals on one SSD) Client network: 10Gbps Cluster network: 10Gbps FIO test: - 2 Client servers - Sequential Read - Run time of 600 seconds - Filesize = 1TB - 10 rbd images per client - Queue depth=16 Any ideas on tuning this cluster? Where should I look first? Thanks, - epk Legal Disclaimer: The information contained in this message may be privileged and confidential. It is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and delete or destroy any copy of this message! PLEASE NOTE: The information contained in this electronic mail message is intended only for the use of the designated recipient(s) named above. If the reader of this message is not the intended recipient, you are hereby notified that you have received this message in error and that any review, dissemination, distribution, or copying of this message is strictly prohibited. If you have received this communication in error, please notify the sender by telephone or e-mail (as shown above) immediately and destroy any and all copies of this message in your possession (whether hard copies or electronically stored copies). Legal Disclaimer: The information contained in this message may be privileged and confidential. It is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and delete or destroy any copy of this message!
_______________________________________________ ceph-users mailing list ceph-users@lists.ceph.com http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com