Hello,

On Tue, 23 Feb 2016 22:49:44 +0900 Christian Balzer wrote:

[snip]
> > 7 nodes(including 3 mons, 3 mds).
> > 9 SATA HDD in every node and each HDD as an OSD&journal(deployed by
> What replication, default of 3?
> 
> That would give the theoretical IOPS of 21 HDDs, but your slow (more
> precisely high latency) network and lack of SSD journals mean it will be
> even lower than that.
> 
[snap]

And when I said 21, I meant of course 10, since w/o SSD journals you're
halving the IOPS of each OSD HDD (and that is being generous).

Christian
-- 
Christian Balzer        Network/Systems Engineer                
ch...@gol.com           Global OnLine Japan/Rakuten Communications
http://www.gol.com/
_______________________________________________
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to