On Mon, Feb 8, 2016 at 10:00 AM, Dzianis Kahanovich
<maha...@bspu.unibel.by> wrote:
> I want to know about plain (not systemd, no deployment tools, only own simple
> "start-stop-daemon" scripts under Gentoo) upgrade hammer to infernalis and see
> no recommendations. Can I simple node-by-node mon+mds+osd's restart or need 
> some
> strict behaviour global per-service restart?
>
> PS "setuser match path = /var/lib/ceph/$type/$cluster-$id" added to config.

All the upstream testing in order upgrades the monitors, then the
OSDs, then RGW/clients/MDSes. Other than that you should be good just
restarting processes, yes.
-Greg