Am 12.03.2014 18:54, schrieb McNamara, Bradley:
> Round up your pg_num and pgp_num to the next power of 2, 2048.

I'm wondering where the "power of two" rule comes from. I can't find it in the
documentation. Moreover, the example at
http://ceph.com/docs/master/rados/configuration/pool-pg-config-ref/ comes out
with 333, which is certainly not a power of two.

If using a power of two for the number of PGs provides a benefit, I would be
happy to know more about it.

Regards

Christian

-- 
Dipl.-Inf. Christian Kauhaus <>< · k...@gocept.com · systems administration
gocept gmbh & co. kg · Forsterstraße 29 · 06112 Halle (Saale) · Germany
http://gocept.com · tel +49 345 219401-11
Python, Pyramid, Plone, Zope · consulting, development, hosting, operations
_______________________________________________
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to