HI,

I have a setup of 3 node ceph cluster : Each ceph node have one monitor and
2 osds running and exposed native device as ceph client.

While I/o was running ,I made network down for 100 seconds on on of ceph
nodes(so one monitor and two osds were down) . For few seconds (~70 sec)
There were no I/os pumping to block device. checked iostat, there was no
change in iops numbers. After sometime, Iops started running as usual.

Please let me is this expected behaviour , and workflow during downtime.

Thanks
Sahana