Hm, is it really necessary to configure all the device paths manually? I'd recommend to use rotational flags to distinguish between OSD and DB/WAL devices. Can you give it a try with a simpler spec file? Something like:

service_type: osd
service_id: node1.ec.all_disks
service_name: osd.node1.ec.all_disks
placement:
  hosts:
    - node1.ec
spec:
  data_devices:
    rotational: 1
  db_devices:
    rotational: 0



Zitat von Alex from North <service.pl...@ya.ru>:

a bit more details. Now I've notices that ceph health detail signals to me that

[WRN] CEPHADM_APPLY_SPEC_FAIL: Failed to apply 1 service(s):
osd.node1.ec.all_disks
osd.node1.ec.all_disks: Expecting value: line 1 column 2311 (char 2310)


Okay, I checked my spec but do not see anything suspicious. Spec itself is here https://pastebin.com/9apchT02


Would be very grateful for the help!
_______________________________________________
ceph-users mailing list -- ceph-users@ceph.io
To unsubscribe send an email to ceph-users-le...@ceph.io


_______________________________________________
ceph-users mailing list -- ceph-users@ceph.io
To unsubscribe send an email to ceph-users-le...@ceph.io