I think using the dashboard you can check for incorrect MTU settings, that
is sometimes an issue.
Brett


On Mon, Mar 3, 2025 at 12:42 PM Ramin Najjarbashi <
ramin.najarba...@gmail.com> wrote:

> The Ceph version is 17.2.7.
>
>
> • OSDs are a mix of SSD and HDD, with DB/WAL colocated on the same OSDs.
>
> • SSDs are used for metadata and index pools with replication 3.
>
> • HDDs store the data pool using EC 4+2.
>
>
> Interestingly, the same issue has appeared on another cluster where DB/WAL
> is placed on NVMe disks, but the pool distribution is the same: meta and
> index on SSDs, and data on HDDs.
>
>
> It seems to be network-related, as I’ve checked the interfaces, and there
> are no obvious hardware or connectivity issues. However, we’re still seeing
> a high number of retransmissions and duplicate packets on the network.
>
>
> Let me know if you have any insights or suggestions.
>
>
> On Mon, Mar 3, 2025 at 12:36 Stefan Kooman <ste...@bit.nl> wrote:
>
> > On 01-03-2025 15:10, Ramin Najjarbashi wrote:
> > > Hi
> > > We are currently facing severe latency issues in our Ceph cluster,
> > > particularly affecting read and write operations. At times, write
> > > operations completely stall, leading to significant service
> degradation.
> > > Below is a detailed breakdown of the issue, our observations, and the
> > > mitigation steps we have taken so far. We would greatly appreciate any
> > > insights or suggestions.
> >
> > What ceph version?
> >
> > How are OSDs provisioned (WAL+DB, single OSD, etc.). Type of disks.
> >
> > Gr. Stefan
> >
> _______________________________________________
> ceph-users mailing list -- ceph-users@ceph.io
> To unsubscribe send an email to ceph-users-le...@ceph.io
>
_______________________________________________
ceph-users mailing list -- ceph-users@ceph.io
To unsubscribe send an email to ceph-users-le...@ceph.io