Only problem is that setting an OSD OUT might not be sticky. If the OSD reboots 
for some reason it might mark itself IN again.

The Ceph cluster distinguishes between manually marked out ("ceph osd out N") and automatically marked out, when an OSD is down for more than 10 minutes.

Manually marked out OSDs do not mark themselves in again.