Den ons 9 okt. 2024 kl 20:48 skrev Frank Schilder <fr...@dtu.dk>:

> The PG count per OSD is a striking exception. Its just a number (well a range 
> with 100 recommended and 200 as a max: 
> https://docs.ceph.com/en/latest/rados/operations/pgcalc/#keyDL). It just is. 
> And this doesn't make any sense unless there is something really evil lurking 
> in the dark.
> For comparison, a guidance that does make sense is something like 100PGs per 
> TB. That I would vaguely understand: to keep the average PG size constant at 
> a max of about 10G.

To be fair, this number could just be something vaguely related to
"spin drives have 100-200 iops", and while cent/rhel linux kernels 10
years ago did have some issues in getting io done in parallel as much
as possible towards a single device, doing multiple OSDs on flash
devices would have been both a way to get around this limitation in
the IO middle layer, and a way to "tell" ceph it can send more IO to
the device since it has multiple OSDs on it.

-- 
May the most significant bit of your life be positive.
_______________________________________________
ceph-users mailing list -- ceph-users@ceph.io
To unsubscribe send an email to ceph-users-le...@ceph.io

Reply via email to