Hi Denis,

we observed the same behaviour here. The cause was that the number of iops discovered at OSD startup was way too high. In our setup the rocksdb is on flash.

When I set osd_mclock_max_capacity_iops_hdd to a value that the HDDs could handle, the situation was resolved, clients got ther fair share of IO.

Hope this helps,

Daniel
--