Hi,

I try to set rdma setting in cluster of 6 nodes (3 mon, 3 OSD Nodes and 10 OSDs 
on each OSD nodes).
OS : CentOS Stream release 8.

I've followed the step bellow, but I got an error.

[root@mon1 ~]# cephadm shell
Inferring fsid 9414e1bc-9061-11ed-90fc-00163e4f92ad
Using recent ceph image 
quay.io/ceph/ceph@sha256:3cd25ee2e1589bf534c24493ab12e27caf634725b4449d50408fd5ad4796bbfa
[ceph: root@mon1 /]# ceph config set global ms_type async+rdma
2023-01-21T11:11:49.182+0000 7fab5922e700 -1 Infiniband verify_prereq!!! 
WARNING !!! For RDMA to work properly user memlock (ulimit -l) must be big 
enough to allow large amount of registered memory. We recommend setting this 
parameter to infinity
/usr/include/c++/8/bits/stl_vector.h:932: std::vector<_Tp, _Alloc>::reference 
std::vector<_Tp, _Alloc>::operator[](std::vector<_Tp, _Alloc>::size_type) [with 
_Tp = Worker*; _Alloc = std::allocator<Worker*>; std::vector<_Tp, 
_Alloc>::reference = Worker*&; std::vector<_Tp, _Alloc>::size_type = long 
unsigned int]: Assertion '__builtin_expect(__n < this->size(), true)' failed.
Aborted (core dumped)
[ceph: root@mon1 /]#

With error I can see suggestion about ulimit, but with a containerized 
deployment, How can I configure properly async+rdma.

Best regards,

_______________________________________________
ceph-users mailing list -- ceph-users@ceph.io
To unsubscribe send an email to ceph-users-le...@ceph.io