There is an IMOD mailing list, and David Mastronarde is very good at answering 
queries. See https://bio3d.colorado.edu/imod/joinlist.html

There seems to be a tutorial for ctfplotter at 
https://bio3d.colorado.edu/imod/doc/CTFexamples.html and the manual 
https://bio3d.colorado.edu/imod/doc/man/ctfplotter.html has some explanation of 
noise files.

You might also want to look into NovaCTF 
https://www.ncbi.nlm.nih.gov/pubmed/28743638 which should be compatible with 
reconstruction in IMOD.

Finally, although the IMOD list is the most appropriate, you could also try the 
CCP-EM list https://www.jiscmail.ac.uk/CCPEM

HTH
m

From: CCP4 bulletin board [mailto:CCP4BB@JISCMAIL.AC.UK] On Behalf Of Carlos 
Lopez
Sent: 09 January 2019 15:54
To: ccp4bb
Subject: [ccp4bb] CTF correction of tomograms

Hi,

I am not sure how to correct CTF in tomography data. I am trying to excute 
ctfplotter, from IMOD, but it cannot read the Noise files. Could someone 
provide a small explanation, or a clear alternative? I have been looking for 
tutorials, but I cannot find nothing clear for tomography.

Many thanks


________________________________

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB&A=1

########################################################################

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB&A=1

Reply via email to