I am experimenting with ALMN cross-rotation using some old known structures.
I was surprised to see what seems to be a requirement for the cell dimensions
of the two crystals to be the same. Is that the case?
Excerpts from the log follow.
eab

 Data line--- CROSS 5 30
. ..
 OPENED INPUT MTZ FILE
 Logical Name: HKLIN   Filename: /a/denzo/als060729/azx02/chbc1azx02r12.mtz
. . .
 * Cell Dimensions : (obsolete - refer to dataset cell dimensions above)
  170.1490  181.3120  240.5010   90.0000   90.0000   90.0000
. . .
 OPENED INPUT MTZ FILE
 Logical Name: HKLIN2   Filename: /a/denzo/ant101master/ant101_complete.mtz
. . .
 * Cell Dimensions : (obsolete - refer to dataset cell dimensions above)
  128.7980  168.5290  231.6520   90.0000   90.0000   90.0000
. . .
 Inconsistency in Cell Dimensions - replacing old:
 Old cell:    170.14900 181.31200 240.50101  90.00000  90.00000  90.00000
 New cell:    128.79800 168.52901 231.65199  90.00000  90.00000  90.00000

If it is really changing the cell parameters of one of the datasets,
won't that distort the patterson and interfere with correlation?
Am I doing something wrong?
The two files are specified as HKLIN and HKLIN2

Reply via email to