Hi Ed, I just had a chance of looking at your comment more closely. You are right it only uses PHIC if in refmacs set up you choose to refine "with prior phase information" -AFAIU. So what exactly is the info contained in the output refmacX.mtz besides map coefficients for COOT? If it is not just the raw xray data Fo, is it Fc only, or Fc that are filled in for missing Fo? I guess I am not really sure. I was under the impression that modelĀ“s PHIC would cause the problems, if they were present. Best,
- Re: [ccp4bb] PHENIX vs REFMAC... Pavel Afonine
- Re: [ccp4bb] PHENIX vs REFMAC refinement h... Eleanor Dodson
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fooled Mark J van Raaij
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fo... Jonathan Elegheert
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fo... Garib N Murshudov
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fooled Jens Kaiser
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fooled Yuri Pompeu
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fooled Yuri Pompeu
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fo... Eleanor Dodson
- Re: [ccp4bb] PHENIX vs REFMAC refinement had me fo... Ed Pozharski
- Re: [ccp4bb] PHENIX vs REFMAC refinement had m... James Holton