The pseudo-free CC in SHELXE is not a very decisive figure of merit. By
far the best way is to run the autotracing (e.g. with -a5) and to look
at the CC for the trace against the native data. A value of more than
25% is almost always solved.
George
On 12/06/2011 10:02 PM, Tiruttani Subhramanyam, Udaya Kumar wrote:
Hi
I forgot to mention the ShelxE beta results in the previous mail
P43212 with 15 sites: Mean FOM = 0.669 , Pseudo-free CC = 69.59 %
P43 with 36 sites: Mean FOM = 0.674, Pseudo-free CC = 70.19 %
P212121 with 36 sites: Mean FOM = 0.689 Pseudo-free CC = 72.08 %
thank you
With regards
uday
------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------