Dear all,

My protein of interest was expressed as secreted protein, so I have to collect 
the medium and change the buffer with sortorius Jet before I load the sample 
onto a IMAC, the buffer change step in my current protocol can last for 12hrs 
(I have to concentrate 4L to 200ml, then dilute it with lysis buffer and 
concentrate it again, then dilute and concentrate repeatedly) and is really 
boring and troublesome, besides I always observe protein loss during this step 
and the detergent in the medium usually concentrate as well in this step which 
would interfere with subsequent purification process. I am wondering if there 
are more convenient ways to capture the target protein from medium? How about 
the following:

1. directly load the medium onto a ion exchange column?

2. Amonium sulfate precipitation?

3. anyother thoughts?

Thank you very much in advance!

Best,

Bei
2011-04-12 



joybeiyang 