*Next MX-proposal application deadline: March 1, 2011 *

We kindly invite new MX-proposals for beamtime applications for the next
beamtime period.

In order to apply for beamtime, please register at the HZB on-line access
tool "BOAT" (http://www.bessy.de/boat/). HZB provides beamtime at the
MX-beamlines 14.1, 14.2 and 14.3. The requested beamtime is  granted
based on the peer-reviewed proposal and reports from previous research
activities. Reported results from previous beamtimes stated in the "Experimental
Reports" form will affect the chances for future beamtimes significantly.
Please make sure to include them if available.

########################################################
        NEWS: HC1c crystal device is now operational on BL14.3
########################################################

Experimental setup:

BL14.1 setup:
- Photon flux: 1.4x10¹¹ Phot/sx100mAx0.05%BW at sample position (0.1-20 sec exposure time per frame)
- User defined beam shaping from 30µm-100µm diameter possible
- MX-225 X-ray detector, 92mm-720mm max. distance from the sample
- Microdiffractometer (MD2) with Mini-kappa goniometer MK3 (STAC controlled)
- Automatic sample changer (CATS), 90 sample storage capacity (SPINE-Pin & EMBL sample magazine compatibility)
- 96-well crystallization plate scanning operational upon request
- Dedicated eight-core XEON-CPU server, with fibre channel SAN up-link data processing environment
- EDNA installed and available
- Common MX software installed including HKL2000, XDS, IMOSFLM, CCP4, Phenix, SHELXC-E, etc.
- Automated data processing with ixds and xdsi available
- Remotely controlled cryo-shutter for crystal annealing
- Bruker AXS X-Flash XRF detector
We are offering the hard- and software environment for carrying out
UVRIP experiments at BL14.1. For further information, please visit:
http://www.helmholtz-berlin.de/forschung/funkma/soft-matter/forschung/bessy-mx/ancillary-facilities/uvrip_en.html

BL14.2 setup:
- Photon flux: 1.9x10¹¹ Phot/sx100mAx0.05%BW at sample position (3-20 sec exposure time per frame) - MX-225 X-ray detector, 45mm-380mm distance from the sample, 30 deg 2-Theta possible
- mardtb goniometer installed
- Dedicated eight-core XEON-CPU server, with fibre channel SAN up-link data processing environment
- EDNA installed and available
- Common MX software installed including HKL2000, XDS, IMOSFLM, CCP4, Phenix, SHELXC-E, etc.
- Automated data processing with ixds and xdsi available
- Remotely controlled cryo-shutter for crystal annealing
- Bruker AXS X-Flash XRF detector
- Pressure chamber for noble gas derivatization (Xe, Kr available upon request) - Ultra high performance stereo microscope Leica M205A, 20-255x zoom, 8 Mpixel CCD-camera

BL14.3 setup:
- Photon flux: 4x10exp10 Phot/sx100mAx0.05%BW at sample position (3-20 sec exposure time per frame) - SX-165 X-ray detector, 45mm-380mm distance from the sample, 30 deg 2-Theta possible
- mardtb goniometer installed
- Dedicated eight-core XEON-CPU server, with fibre channel SAN up-link data processing environment
- EDNA installed and available
- Common MX software installed including HKL2000, XDS, IMOSFLM, CCP4, Phenix, SHELXC-E, etc.
- Automated data processing with ixds and xdsi available
- Remotely controlled cryo-shutter for crystal annealing
- HC-1c dehydration device installed, HC1-beamtime upon request
- Pressure chamber for noble gas derivatization (Xe, Kr available upon request) - Ultra high performance stereo microscope Leica M205A, 20-255x zoom, 8 Mpixel CCD-camera

Please visit our web page www.helmholtz-berlin.de/bessy-mx to gain updated
information about our experimental setup and other requirements.

Uwe Mueller, Manfred Weiss and the HZB BESSY-MX group

--
Dr. Manfred. S. Weiss
Helmholtz-Zentrum Berlin für Materialien und Energie
Macromolecular Crystallography (BESSY-MX)
Albert-Einstein-Str. 15
D-12489 Berlin
GERMANY
Fon:   +49-30-806213149
Fax:   +49-30-806214975
Web:   http://www.helmholtz-berlin.de/bessy-mx
Email: mswe...@helmholtz-berlin.de

<i>Helmholtz-Zentrum Berlin für Materialien und Energie GmbH
Hahn-Meitner-Platz 1, 14109 Berlin
Vorsitzender des Aufsichtsrats: Prof. Dr. Dr. h.c. mult. Joachim Treusch
Stellvertretende Vorsitzende: Dr. Beatrix Vierkorn-Rudolph
Geschäftsführer: Prof. Dr. Anke Rita Kaysser-Pyzalla, Prof. Dr. Dr. h.c.
Wolfgang Eberhardt, Dr. Ulrich Breuer
Sitz der Gesellschaft: Berlin
Handelsregister: AG Charlottenburg, 89 HRB 5583</i>

Reply via email to