Few people had complains about this. It seems to be related with
compilation. If you take the version from York's website then it
should work fine.
www.ysbl.york.ac.uk/refmac/latest_refmac.html
I have compiled it for mac 10.5 and it does not seem to work on mac
10.4. I am trying to make it platform independent but if you want 10.4
then I can compile the latest version for this platform also.
regards
Garib
On 23 Oct 2009, at 14:04, Ian Tickle wrote:
All – we’re having a problem with Refmac (version 5.5.0102) in CCP4
6.1.2 that I compiled from source using ifort v11.0 on Centos 4.6.
When I refine a structure with a HIS in alternate conformations (all
atoms except N, C & O doubled up) it completely destroys the
sidechains of both copies. Same thing happens with any other
residue type (e.g. SER). All single-conformer residues, including
some ligands are fine.
Has anyone else noticed this? Is this a known problem with this
version/compiler/OS?
Cheers
-- Ian
********************************************
Ian J. Tickle, DPhil.
Director of X-ray Technology
Astex Therapeutics Ltd
436 Cambridge Science Park
Milton Road, Cambridge
CB4 0QA, UK
Tel: +44(0)1223 226214
Fax: +44(0)1223 226201
www.astex-therapeutics.com
Disclaimer
This communication is confidential and may contain privileged
information intended solely for the named addressee(s). It may not
be used or disclosed except for the purpose for which it has been
sent. If you are not the intended recipient you must not review,
use, disclose, copy, distribute or take any action in reliance upon
it. If you have received this communication in error, please notify
Astex Therapeutics Ltd by emailing i.tic...@astex-therapeutics.com
and destroy all copies of the message and any attached documents.
Astex Therapeutics Ltd monitors, controls and protects all its
messaging traffic in compliance with its corporate email policy. The
Company accepts no liability or responsibility for any onward
transmission or use of emails and attachments having left the Astex
Therapeutics domain. Unless expressly stated, opinions in this
message are those of the individual sender and not of Astex
Therapeutics Ltd. The recipient should check this email and any
attachments for the presence of computer viruses. Astex Therapeutics
Ltd accepts no liability for damage caused by any virus transmitted
by this email. E-mail is susceptible to data corruption,
interception, unauthorized amendment, and tampering, Astex
Therapeutics Ltd only send and receive e-mails on the basis that the
Company is not liable for any such alteration or any consequences
thereof.
Astex Therapeutics Ltd., Registered in England at 436 Cambridge
Science Park, Cambridge CB4 0QA under number 3751674