Hi,

Indeed, I just tested version 5.3.0040, and there the ANISO seems to work.

~L~

_______________________________________

 Lari Lehtiƶ
 Structural Genomics Consortium
 Medical Biochemistry & Biophysics Dept.                   
 Karolinska Institute
 Stockholm, Sweden
_______________________________________

----- Original Message -----
From: Ian Tickle <[EMAIL PROTECTED]>
Date: Wednesday, September 19, 2007 2:22 pm
Subject: Re: [ccp4bb] anisotropic scaling in refmac versions
To: CCP4BB@JISCMAIL.AC.UK

> I think this isn't a problem in the latest version of Refmac (0040 
> I think), so try downloading it from the York site.
> 
> -- Ian 
> 
> > -----Original Message-----
> > From: [EMAIL PROTECTED] 
> > [mailto:[EMAIL PROTECTED] On Behalf Of Alejandro 
> Buschiazzo> Sent: 19 September 2007 13:20
> > To: Lari Lehtio
> > Cc: CCP4BB@JISCMAIL.AC.UK
> > Subject: Re: [ccp4bb] anisotropic scaling in refmac versions
> > 
> > Hello,
> > I wonder if there was any direct answer to the question that 
> > Lari made a 
> > couple of days ago.
> > Sorry if I missed it, but I believe there wasn't any response to 
> the 
> > ccp4bb...
> > 
> > thanks
> > 
> > Alejandro
> > 
> > 
> > Lari Lehtio wrote:
> > > Dear All,   
> > >   
> > > I just came back from the beam line and started to continue 
> > my work on a structure that I solved  
> > > while collecting other data. I noticed that my R-factors 
> > were a lot higher at home lab although  
> > > I was using the exact same input files.   
> > >   
> > > I then noticed that the version was different:   
> > >   
> > > The one giving lower R-factors was   
> > > Refmac_5.2.0019    version 5.2.0019  : 06/09/05  
> > >   
> > > And the one giving higher:  
> > > Refmac_5.3.0032    version 5.3.0032  : 02/16/06  
> > >   
> > > I happened to have the older version also in my home pc, so 
> > I tried again and indeed, 5.2.0019  
> > > gives lower R-factors.   
> > >   
> > > The input command is identical, but when I "diffed" the 
> > pdb-files, I noticed that anisotropic 
> > > scale is missing in the newer files. Did I make a mistake? 
> > How can I turn it back on.  
> > >  
> > > Below is the diff output and the command used for refmac. 
> > >  
> > > Thank you in advance, 
> > >  
> > > ~L~ 
> > >  
> > > < REMARK   3   PROGRAM     : REFMAC 5.2.0019 
> > >   
> > >> REMARK   3   PROGRAM     : REFMAC 5.3.0032 
> > >>     
> > > < REMARK   3   R VALUE     (WORKING + TEST SET) : 0.21101 
> > > < REMARK   3   R VALUE            (WORKING SET) :  0.20867 
> > > < REMARK   3   FREE R VALUE                     :  0.25559 
> > >   
> > >> REMARK   3   R VALUE     (WORKING + TEST SET) : 0.23077 
> > >> REMARK   3   R VALUE            (WORKING SET) :  0.22807 
> > >> REMARK   3   FREE R VALUE                     :  0.28228 
> > >>     
> > > < REMARK   3   BIN R VALUE           (WORKING SET) :    0.240 
> > >   
> > >> REMARK   3   BIN R VALUE           (WORKING SET) :    0.262 
> > >>     
> > > < REMARK   3   BIN FREE R VALUE                    :    0.288 
> > >   
> > >> REMARK   3   BIN FREE R VALUE                    :    0.343 
> > >>     
> > > < REMARK   3   MEAN B VALUE      (OVERALL, A**2) :  25.271 
> > >   
> > >> REMARK   3   MEAN B VALUE      (OVERALL, A**2) :  29.941 
> > >>     
> > > < REMARK   3    B11 (A**2) :     2.35 
> > > < REMARK   3    B22 (A**2) :    -1.99 
> > > < REMARK   3    B33 (A**2) :     0.32 
> > >   
> > >> REMARK   3    B11 (A**2) :     0.00 
> > >> REMARK   3    B22 (A**2) :     0.00 
> > >> REMARK   3    B33 (A**2) :     0.00 
> > >>     
> > > < REMARK   3    B13 (A**2) :     0.90 
> > >   
> > >> REMARK   3    B13 (A**2) :     0.00 
> > >>     
> > >  
> > > 
> > ______________________________________________________________
> > _______________________ 
> > > make check NONE 
> > > make - 
> > >     hydrogen YES - 
> > >     hout NO - 
> > >     peptide NO - 
> > >     cispeptide YES - 
> > >     ssbridge YES - 
> > >     symmetry YES - 
> > >     sugar YES - 
> > >     connectivity NO - 
> > >     link NO 
> > > refi - 
> > >     type REST - 
> > >     resi MLKF - 
> > >     meth CGMAT - 
> > >     bref ISOT 
> > > ncyc 10 
> > > scal - 
> > >     type SIMP - 
> > >     reso 2.100 19.976 - 
> > >     LSSC - 
> > >     ANISO - 
> > >     EXPE 
> > > solvent YES - 
> > >     VDWProb 1.4 - 
> > >     IONProb 0.8 - 
> > >     RSHRink 0.8 
> > > weight - 
> > >     MATRIX 0.1 
> > > monitor MEDIUM - 
> > >     torsion 10.0 - 
> > >     distance 10.0 - 
> > >     angle 10.0 - 
> > >     plane 10.0 - 
> > >     chiral 10.0 - 
> > >     bfactor 10.0 - 
> > >     bsphere 10.0 - 
> > >     rbond 10.0 - 
> > >     ncsr 10.0 
> > > labin  FP=FP SIGFP=SIGFP - 
> > >    FREE=FreeRflag 
> > > labout  FC=FC FWT=FWT PHIC=PHIC PHWT=PHWT DELFWT=DELFWT 
> > PHDELWT=PHDELWT FOM=FOM 
> > > PNAME unknown 
> > > DNAME unknown130907 
> > > RSIZE 80 
> > > END 
> > >  
> > > _______________________________________  
> > >   
> > >  Lari Lehtiƶ  
> > >  Structural Genomics Consortium  
> > >  Medical Biochemistry & Biophysics Dept.                     
> > >  Karolinska Institute  
> > >  Stockholm, Sweden  
> > > _______________________________________  
> > >   
> > >
> > >   
> > 
> > 
> > -- 
> > Alejandro Buschiazzo, PhD
> > Research Scientist
> > Laboratory of Structural Biology
> > Pasteur Institute of Montevideo
> > Mataojo 2020
> > Montevideo 11400
> > URUGUAY
> > 
> > Phone: +5982 5220910 int. 120
> > Fax:   +5982 5224185
> > 
> > 
> 
> 
> Disclaimer
> This communication is confidential and may contain privileged 
> information intended solely for the named addressee(s). It may not 
> be used or disclosed except for the purpose for which it has been 
> sent. If you are not the intended recipient you must not review, 
> use, disclose, copy, distribute or take any action in reliance upon 
> it. If you have received this communication in error, please notify 
> Astex Therapeutics Ltd by emailing [EMAIL PROTECTED] 
> and destroy all copies of the message and any attached documents. 
> Astex Therapeutics Ltd monitors, controls and protects all its 
> messaging traffic in compliance with its corporate email policy. 
> The Company accepts no liability or responsibility for any onward 
> transmission or use of emails and attachments having left the Astex 
> Therapeutics domain.  Unless expressly stated, opinions in this 
> message are those of the individual sender and not of Astex 
> Therapeutics Ltd. The recipient should check this email and any 
> attachments for the presence of computer viruses. Astex 
> Therapeutics Ltd accepts no liability for damage caused by any 
> virus transmitted by this email. E-mail is susceptible to data 
> corruption, interception, unauthorized amendment, and tampering, 
> Astex Therapeutics Ltd only send and receive e-mails on the basis 
> that the Company is not liable for any such alteration or any 
> consequences thereof.
> Astex Therapeutics Ltd., Registered in England at 436 Cambridge 
> Science Park, Cambridge CB4 0QA under number 3751674
>

Reply via email to