As a side-note, depending on your requirements in the real world, you
can use multi-VRF selection using PBR.

This allows you to run your routing protocol in the 'ip vrf forwarding'
VRF and switch VRF for your other traffic using PBR with 'set ip vrf
BLAH next-hop' and 'ip vrf receive' on the interface.

I don't think you'd see this in the SP lab.


--Dan 

> -----Original Message-----
> From: [email protected] [mailto:ccie_sp-
> [email protected]] On Behalf Of Rick Mur
> Sent: 29 October 2009 23:14
> To: Bryan Bartik
> Cc: ccie_sp
> Subject: Re: [OSL | CCIE_SP] VRF select and dynamic protocols
> 
> From my understanding VRF-select can ONLY be done with static routing.
It's
> also the reason why I can't think of any implementation of this in
real-life
> as you get a LOT of static routes :-)
> 
> 
> --
> 
> Regards,
> 
> Rick Mur
> CCIE2 #21946 (R&S / Service Provider)
> Sr. Support Engineer - IPexpert, Inc.
> URL: http://www.IPexpert.com <http://www.IPexpert.com/>
> 
> On 29 okt 2009, at 17:09, Bryan Bartik wrote:
> 
> 
>       Good question, I don't see how it would be possible since like
you
> said, the interface does not belong to one VRF. It would be
interesting to
> hear if it can be done.
> 
> 
>       On Wed, Oct 28, 2009 at 11:24 PM, Jose Zamora
<[email protected]>
> wrote:
> 
> 
> 
>               Hi guys.. i want to now if there is a way to set-up vrf
select
> using dynamic protocols between the PE/CE, i just tested it  with
several
> protocols but did not  workout .
> 
>               In all the tests it seems like  is not possible to
achieve
> this because the protocols did not see any interface associated with
the
> vrf.
> 
>               But i i didn't find any place that can confirm/drop
this.
> 
> 
> 
>               Regards
> 
> 
>               Jose
> 
>               _______________________________________________
>               For more information regarding industry leading CCIE Lab
> training, please visit www.ipexpert.com <http://www.ipexpert.com/>
> 
> 
> 
> 
> 
> 
>       --
>       Bryan Bartik
>       CCIE #23707 (R&S), CCNP
>       Sr. Support Engineer - IPexpert, Inc.
>       URL: http://www.IPexpert.com <http://www.IPexpert.com/>
>       _______________________________________________
>       For more information regarding industry leading CCIE Lab
training,
> please visit www.ipexpert.com
> 
> 

This email has been scanned for all viruses.

Please consider the environment before printing this email.

The content of this email and any attachment is private and may be privileged. 
If you are not the intended recipient, any use, disclosure, copying or 
forwarding of this email and/or its attachments is unauthorised. If you have 
received this email in error please notify the sender by email and delete this 
message and any attachments immediately. Nothing in this email shall bind the 
Company or any of its subsidiaries or businesses in any contract or obligation, 
unless we have specifically agreed to be bound.

KCOM Group PLC is a public limited company incorporated in England and Wales, 
company number 02150618 and whose registered office is at 37 Carr Lane, Hull, 
HU1 3RE.

118288 - KCOM UK Directory Enquiries. Calls will cost no more than 49p 
connection + 14p per minute including VAT from a KC or BT landline. Call 
charges from mobiles and other networks may vary. If you are calling from a 
mobile you will now receive your requested number via text message. You will 
not be charged for the text message.

_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to