Multilink as you are combining the serial interfaces ... I think. So each
serial interface has a defined BW (which is shared by the sub interfaces),
but your combining them so you need to tell the logical multilink what the
cumulative is. ACtually saying that MLPPP usually take this into
consideration, but I guess as you are using QoS you need to manually define
it.

Thoughts? am I off the mark?

B

On Tue, May 8, 2012 at 3:56 AM, marc abel <[email protected]> wrote:

> If I am doing FRTS on a ppp multi-link interface where should I set the
> bandwidth? On the physical interface, the sub interface, or the multilink
> interface?
>
> Thank you,
>
> Marc
> _______________________________________________
> For more information regarding industry leading CCIE Lab training, please
> visit www.ipexpert.com
>
> Are you a CCNP or CCIE and looking for a job? Check out
> www.PlatinumPlacement.com
>
> http://onlinestudylist.com/mailman/listinfo/ccie_rs
>
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out 
www.PlatinumPlacement.com

http://onlinestudylist.com/mailman/listinfo/ccie_rs