Samuel Thibault, on Wed 16 Nov 2016 19:50:07 +0100, wrote:
> Samuel Thibault, on Wed 16 Nov 2016 19:46:52 +0100, wrote:
> > The attached testcase does get the faulting address.
> 
> And the attached testcase doesn't.

And is fixed by the attached patch, could you try it?

Samuel
Index: glibc-2.24/sysdeps/mach/hurd/i386/trampoline.c
===================================================================
--- glibc-2.24.orig/sysdeps/mach/hurd/i386/trampoline.c
+++ glibc-2.24/sysdeps/mach/hurd/i386/trampoline.c
@@ -90,7 +90,7 @@ _hurd_setup_sighandler (struct hurd_sigs
   void firewall (void);
   extern const void _hurd_intr_rpc_msg_cx_sp;
   extern const void _hurd_intr_rpc_msg_sp_restored;
-  struct sigaction *action;
+  const struct sigaction *action;
   void *volatile sigsp;
   struct sigcontext *scp;
   struct
@@ -123,6 +123,11 @@ _hurd_setup_sighandler (struct hurd_sigs
       siginfo_t siginfo;
     } *stackframe;
 
+  /* sigaction for preemptors */
+  static const struct sigaction legacy_sigaction = {
+    .sa_flags = SA_RESTART
+  };
+
   if (ss->context)
     {
       /* We have a previous sigcontext that sigreturn was about
@@ -146,9 +151,13 @@ _hurd_setup_sighandler (struct hurd_sigs
      interrupted RPC frame.  */
   state->basic.esp = state->basic.uesp;
 
-  /* XXX what if handler != action->handler (for instance, if a signal
-   * preemptor took over) ? */
   action = & _hurd_sigstate_actions (ss) [signo];
+  if ( (action->sa_flags & SA_SIGINFO)
+        && handler != (__sighandler_t) action->sa_sigaction
+   || !(action->sa_flags & SA_SIGINFO)
+        && handler != action->sa_handler)
+    /* A signal preemptor took over, use legacy semantic.  */
+    action = &legacy_sigaction;
 
   if ((action->sa_flags & SA_ONSTACK) &&
       !(ss->sigaltstack.ss_flags & (SS_DISABLE|SS_ONSTACK)))

Reply via email to