Hello!

There is a fundamental principle in BIRD that one BIRD table may be synced to 
at most one kernel table. Use BIRD pipe pseudoprotocol to duplicate the routes 
to more BIRD tables.

This concept may be changed in future, yet not in near future.

Maria 

On June 1, 2020 7:58:39 PM GMT+02:00, Matt Corallo <birdl...@as397444.net> 
wrote:
>When trying to sync a BIRD routing table to multiple kernel routing
>tables (with different export filters, obviously),
>BIRD refuses with, eg, "Kernel syncer (v6kern) already attached to
>table master6". Is this something that is fundamental
>or would be it easy to address this by allowing it if the "kernel
>table" field has a different value?
>
>Thanks,
>Matt

-- 
Sent from my Android device with K-9 Mail. Please excuse my brevity.

Reply via email to