Hi Ondřej! We run Ubuntu 24.04. Can you please update the dev-ppa too?
Thanks Klaus -- Klaus Darilion, Head of Operations nic.at GmbH, Jakob-Haringer-Straße 8/V 5020 Salzburg, Austria From: Ondřej Surý <ond...@isc.org> Sent: Monday, December 9, 2024 2:54 PM To: Klaus Darilion <klaus.daril...@nic.at> Cc: Klaus Darilion via bind-users <bind-users@lists.isc.org> Subject: Re: Sporadic Timeouts after upgrading to bind9.20 Hi Klaus, the bind-dev repository is now at 9.21.2-302-gebe0db5daad-1 as I remember you are using Debian on the servers, right? Could you test that version if you can see the same timeouts you've been encountering before? Thanks, Ondrej -- Ondřej Surý (He/Him) ond...@isc.org<mailto:ond...@isc.org> My working hours and your working hours may be different. Please do not feel obligated to reply outside your normal working hours. On 6. 12. 2024, at 0:28, Klaus Darilion <klaus.daril...@nic.at<mailto:klaus.daril...@nic.at>> wrote: Hi Ondřej! I can test also the development branch. I prefer deb packages (do you have nightly builds?), but I can fallback to make&&make install Regards KLaus From: Ondřej Surý <ond...@isc.org<mailto:ond...@isc.org>> Sent: Thursday, December 5, 2024 8:36 PM To: Klaus Darilion <klaus.daril...@nic.at<mailto:klaus.daril...@nic.at>> Cc: Klaus Darilion via bind-users <bind-users@lists.isc.org<mailto:bind-users@lists.isc.org>> Subject: Re: Sporadic Timeouts after upgrading to bind9.20 Hi Klaus, we've identified an issue in the glue cache that have been causing drops in the performance. Can you test a development branch or do you need fix on top of 9.20? Ondrej -- Ondřej Surý (He/Him) ond...@isc.org<mailto:ond...@isc.org> My working hours and your working hours may be different. Please do not feel obligated to reply outside your normal working hours. On 9. 9. 2024, at 10:39, Klaus Darilion via bind-users <bind-users@lists.isc.org<mailto:bind-users@lists.isc.org>> wrote: As we still have several timeouts I downgraded our server to 9.18. If you know another workaround or need someone to test new version please let me know. Thanks Klaus From: Klaus Darilion <klaus.daril...@nic.at<mailto:klaus.daril...@nic.at>> Sent: Saturday, September 7, 2024 12:36 AM To: Klaus Darilion <klaus.daril...@nic.at<mailto:klaus.daril...@nic.at>>; Ondřej Surý <ond...@isc.org<mailto:ond...@isc.org>> Cc: Klaus Darilion via bind-users <bind-users@lists.isc.org<mailto:bind-users@lists.isc.org>> Subject: RE: Sporadic Timeouts after upgrading to bind9.20 Correcting myself: event with { reuseport no; }; and UV_THREADPOOL_SIZE=12 still timeouts happen, but the situation improved a lot. Regards Klaus From: bind-users <bind-users-boun...@lists.isc.org<mailto:bind-users-boun...@lists.isc.org>> On Behalf Of Klaus Darilion via bind-users Sent: Saturday, September 7, 2024 12:21 AM To: Ondřej Surý <ond...@isc.org<mailto:ond...@isc.org>> Cc: Klaus Darilion via bind-users <bind-users@lists.isc.org<mailto:bind-users@lists.isc.org>> Subject: RE: Sporadic Timeouts after upgrading to bind9.20 From: Ondřej Surý <ond...@isc.org<mailto:ond...@isc.org>> Sent: Friday, September 6, 2024 4:08 PM To: Klaus Darilion <klaus.daril...@nic.at<mailto:klaus.daril...@nic.at>> Cc: Petr Špaček <pspa...@isc.org<mailto:pspa...@isc.org>>; bind-users@lists.isc.org<mailto:bind-users@lists.isc.org>; Klaus Darilion via bind-users <bind-users@lists.isc.org<mailto:bind-users@lists.isc.org>> Subject: Re: Sporadic Timeouts after upgrading to bind9.20 Are your running with options { reuseport no; }; ? You might want to try that. After setting reuseport no; (and UV_THREADPOOL_SIZE=12) I have not seen any timeouts anymore. Anyway, this: TID 8917: #0 0x00007b385aa6daa9 cds_lfht_destroy - /usr/lib/x86_64-linux-gnu/liburcu-cds.so<http://liburcu-cds.so/>.8.1.0 caught my eye. Are the zones you are hosting particularly large on GLUE? I don’T know and I have not checked yet. One of the affected zones is .ch. You could download the zone fromhttps://zonedata.switch.ch/ And they are using NSEC (not NSEC3 as I have written before) Also if you have more eu-stack, can you confirm this is the pattern now? After setting reuseport no; I do not have stack-traces any more. But if that would help you I can undo the workaround next week to collect traces. Thanks Klaus -- Visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe from this list ISC funds the development of this software with paid support subscriptions. Contact us at https://www.isc.org/contact/ for more information. bind-users mailing list bind-users@lists.isc.org<mailto:bind-users@lists.isc.org> https://lists.isc.org/mailman/listinfo/bind-users
-- Visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe from this list ISC funds the development of this software with paid support subscriptions. Contact us at https://www.isc.org/contact/ for more information. bind-users mailing list bind-users@lists.isc.org https://lists.isc.org/mailman/listinfo/bind-users