In message <20160823015248.02edc3f2@workstation.bitcorner.intern>, Andreas Meye r writes: > Andreas Meyer <a.me...@nimmini.de> schrieb am 23.08.16 um 00:18:02 Uhr: > > > > After reloading or stopping and starting the serial is not changed > > > and shows a value serial 2016080310. > > > > > > Why is the serial not updated? > > > > I found out that the signed zone is not updated with a reload or > > restart of bind9 but with a rndc reload it is. > > No, it is not :( > > Andreas
The inline serial is mostly independent of the raw zone file. BIND 9.11 has: rndc signing -serial <value> zone [class [view]] Mark -- Mark Andrews, ISC 1 Seymour St., Dundas Valley, NSW 2117, Australia PHONE: +61 2 9871 4742 INTERNET: ma...@isc.org _______________________________________________ Please visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe from this list bind-users mailing list bind-users@lists.isc.org https://lists.isc.org/mailman/listinfo/bind-users