On 26 zones I don’t think the load will be a problem. A few seconds on reload time won’t affect me one way or the other. Regardless, I have changed the webmin command to rndc reload.
Jeff > On Apr 14, 2015, at 6:05 PM, Stuart Browne <stuart.bro...@bomboratech.com.au> > wrote: > >> On 14.04.15 07:36, SH Development wrote: >>> Like what? I’ve never had any issues. >> >> Like you uselessly flush all cached data, RTTs ... and you get unwanted log >> line in the output. >> >> If you never had any issues with reconfig, use rndc reconfig. >> >>>> On Apr 13, 2015, at 12:27 PM, Emil Natan <shly...@gmail.com> wrote: >>>>> in other words: if you everytime you change the config hard restart >>>>> named instead a reload you are doing it terrible wrong with a ton of bad >>>>> side effects > > Let's not forget that every time you restart named, you have to reload all > your zones from scratch. If you're only running a small number of small > zones, this probably doesn't mean much. If you're running hundreds (or even > thousands) of zones with millions of records, the time loss on a restart is > quite significant, even if you are running the latest bind using compiled > (memory map) zone files on disk. > > Stuart > _______________________________________________ > Please visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe > from this list > > bind-users mailing list > bind-users@lists.isc.org > https://lists.isc.org/mailman/listinfo/bind-users _______________________________________________ Please visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe from this list bind-users mailing list bind-users@lists.isc.org https://lists.isc.org/mailman/listinfo/bind-users