Udo Kaune schrieb am 13.06.25 um 23:47:
Hi Thorsten,
Did you reboot the box recently and did by any chance your devices get
reordered?
What does lsscsi -g show and does that correspond to your
bacula-sd.conf entries?
Best regards, Udo
Hi Udo,
yes, I regularily reboot the system for maintenance:
sudo lsscsi -g
[0:0:0:0] disk Areca ARC-1883-VOL#000 R001 /dev/sda /dev/sg0
[0:0:0:1] disk Areca ARC-1883-VOL#001 R001 /dev/sdb /dev/sg1
[0:0:0:2] disk Areca Data6 R001 /dev/sdc /dev/sg2
[0:0:0:4] disk Areca VOL_Data4 R001 /dev/sdd /dev/sg3
[0:0:16:0] process Areca RAID controller R001 - /dev/sg4
[1:0:0:0] enclosu ATTO VirtualSES 0001 - /dev/sg6
[1:0:1:0] tape IBM ULTRIUM-HH9 R3G1 /dev/st0 /dev/sg7
[1:0:1:1] mediumx BDT FlexStor II 6.21 /dev/sch0 /dev/sg8
That looks very susual and it worked in the last months with sg7
Now, just for the fun of it I used mtx -f /dev/sg8 status additionally
and got:
mtx: Request Sense: Long Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=70 (Current)
mtx: Request Sense: Sense Key=Unit Attention
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx: Request Sense: ILI=no
mtx: Request Sense: Additional Sense Code = 2A
mtx: Request Sense: Additional Sense Qualifier = 01
mtx: Request Sense: BPV=no
mtx: Request Sense: Error in CDB=no
mtx: Request Sense: SKSV=no
Mode sense (0x1A) for Page 0x1D failed
Storage Changer /dev/sg8:1 Drives, 24 Slots ( 0 Import/Export )
Data Transfer Element 0:Full (Storage Element 13 Loaded):VolumeTag =
000050CU
Storage Element 1:Full :VolumeTag=000003L9
Storage Element 2:Full :VolumeTag=000006L9
Storage Element 3:Full :VolumeTag=000009L9
Storage Element 4:Full :VolumeTag=000012L9
Storage Element 5:Full :VolumeTag=000002L9
Storage Element 6:Full :VolumeTag=000005L9
Storage Element 7:Full :VolumeTag=000008L9
Storage Element 8:Full :VolumeTag=000011L9
Storage Element 9:Full :VolumeTag=000001L9
Storage Element 10:Full :VolumeTag=000004L9
Storage Element 11:Full :VolumeTag=000007L9
Storage Element 12:Full :VolumeTag=000010L9
Storage Element 13:Empty
Storage Element 14:Full :VolumeTag=000021L9
Storage Element 15:Full :VolumeTag=000018L9
Storage Element 16:Full :VolumeTag=000015L9
Storage Element 17:Full :VolumeTag=000023L9
Storage Element 18:Full :VolumeTag=000020L9
Storage Element 19:Full :VolumeTag=000017L9
Storage Element 20:Full :VolumeTag=000014L9
Storage Element 21:Full :VolumeTag=000022L9
Storage Element 22:Full :VolumeTag=000019L9
Storage Element 23:Full :VolumeTag=000016L9
Storage Element 24:Full :VolumeTag=000013L9
As this surprisingly looked more like a changer, despite the error
code=70, I changed the changer path in bacula-sd.conf to /dev//sg8
Then I ran a backup (catalogue to make it quick):
*And to my surprise - the backup worked again. *
Now, this is a big surprise. I would not check the devices if despite
many reboots (both, host and changer) all of a sudden the device is not
correct. To be honest, that would probably be something I would not have
looked into....
Thanks. You made my weekend.
Cheers
T
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users