Hello,

pon., 5 sie 2024 o 18:42 Dr. Thorsten Brandau <thorsten.bran...@brace.de>
napisał(a):

> Hi Rob,
>
> I updated the slots. THEN (yes, yes, shame on me) I checked the messages.
> In my email below I reacted to an error messages via email... It seems as
> there was a time out when loading the tape, which was recovered by after
> some time:
>
>
> 05-Aug 16:09 -sd JobId 908: 3305 Autochanger "load Volume 000023L9, Slot
> 17, Drive 0", status is OK.
> 05-Aug 16:09 -sd JobId 908: Warning: mount.c:216 Open of Tape device
> "LTO9-1" (/dev/nst0) Volume "000023L9" failed: ERR=tape_dev.c:169 Unable to
> open device "LTO9-1" (
> /dev/nst0): ERR=Eingabe-/Ausgabefehler
>
...

> Still confused about the error message, but it seems as there are some
> self-healing capabilities involved.
>

Most probably it is a LTO9 calibration phase.

-- 
Radosław Korzeniewski
rados...@korzeniewski.net