I've setup in my pool(s) the 'Cleaning Prefix' and addedd to the library the
cleaning tape; situation now is:

 *update slots storage=CNPVE3Autochanger
 Connecting to Storage daemon CNPVE3Autochanger at cnpve3.cn.lnf.it:9103 ...
 3306 Issuing autochanger "slots" command.
 Device "Autochanger" has 8 slots.
 Connecting to Storage daemon CNPVE3Autochanger at cnpve3.cn.lnf.it:9103 ...
 3306 Issuing autochanger "list" command.
 Catalog record for Volume "AAJ666L9" is up to date.
 Catalog record for Volume "AAJ667L9" is up to date.
 Volume "CLN001L9" not found in catalog. Slot=8 InChanger set to zero.

I've tried to mount cleaning cartdrige but:

 *mount storage=CNPVE3Autochanger slot=8
 3304 Issuing autochanger "load Volume , Slot 8, Drive 0" command.
 3305 Autochanger "load Volume , Slot 8, Drive 0", status is OK.
 3901 Unable to open device ""LTO9Storage0" (/dev/nst0)": ERR=tape_dev.c:170 
Unable to open device "LTO9Storage0" (/dev/nst0): ERR=Input/output error

This seems also pretty logic: bacula mount the cartdrige and (try to) read
it, but this is a clieaning one...
Anyway, i've waited the command to end, then i've tried also:

 *unmount storage=CNPVE3Autochanger
 3307 Issuing autochanger "unload Volume *Unknown*, Slot 8, Drive 0" command.
 3901 Device ""LTO9Storage0" (/dev/nst0)" is already unmounted.

after that, anyway, cleaning cartdrige was back on slot 8 (probably the
previous mount failed early and anyway cleaning tape was just on the route to
slot 8).


I've the doubt i'm doing something wrong, eg i don't have to use '(u)mount
storage' command from bacula console to mount cleaning cartdrige, but use
insted direct library command via mtx-changer script, for example.


Someone have some clue? Thanks.

-- 




_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to