Hello, czw., 29 lut 2024 o 22:41 Marco Gaiarin <g...@lilliput.linux.it> napisał(a):
> 2) there's a 'tape-unit calibration' procedure to accomplish: for every NEW > cartdrige, the first time you insert it you have to wait for the > calibration to complete (1-2 hour for every tape). > >From my experience a calibration takes place for every new cartridge on every drive. So, if you have multiple drives then multiple calibrations for single tape. best regards -- Radosław Korzeniewski rados...@korzeniewski.net
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users