On 3/31/23 10:16, Peter N. Steinmetz wrote:
Hi Matlink and Bill,

Thanks for those suggestions and explanation of why Bacula won’t automatically label a new volume because the pool is full.

I agree that the puzzle now is why it is not recycling one of the purged volumes in that pool?

Are the oldest volumes *actually fully purged*?

Do you have Recycle Oldest Volume enabled?

(Actually, I don't recycle disk volumes. I delete them on purge and create new ones as needed. I find it simplifies volume tracking and makes better use of disk space.)



--
  Phil Stracchino
  Babylon Communications
  ph...@caerllewys.net
  p...@co.ordinate.org
  Landline: +1.603.293.8485
  Mobile:   +1.603.998.6958