I used Bacula 7.4.5 successfully for around 2 years with an IBM
ULTRIUM-HH7 SAS drive and FlexStor II autoloader (Neoseries) on Arch
Linux. Backups and restores worked perfectly.

Last month I upgraded to Bacula 9.2.2. Backups worked without error but
I noticed "list volumes" reporting a 25 TB volume (not 6 TB as usual). A
subsequent test restore failed due to a volume data error.

I followed the Bacula troubleshooting web page [1], trying mt defblksize
0 then a btape test. This reported the same error.

Downgrading back to Bacula 7.4.5 did not resolve the issue.

I upgraded to Bacula 9.4.1 but the issue remains.

A log of the commands and configuration is below.

Any suggestions on what to try next much appreciated. Thanks.


[root@fs1 etc]# mt -f /dev/nst0 defblksize 0

[root@fs1 etc]# mt -f /dev/nst0 status
SCSI 2 tape drive:
File number=0, block number=0, partition=0.
Tape block size 0 bytes. Density code 0x5c (no translation).
Soft error count since last status=0
General status bits on (41010000):
 BOT ONLINE IM_REP_EN

[root@fs1 etc]# btape -c /etc/bacula/bacula-sd.conf /dev/nst0
Tape block granularity is 1024 bytes.
btape: butil.c:290-0 Using device: "/dev/nst0" for writing.
btape: btape.c:478-0 open device "LTO-7" (/dev/nst0): OK
*test

=== Write, rewind, and re-read test ===

I'm going to write 10000 records and an EOF
then write 10000 records and an EOF, then rewind,
and re-read the data to verify that it is correct.

This is an *essential* feature ...

btape: btape.c:1161-0 Wrote 10000 blocks of 64412 bytes.
btape: btape.c:612-0 Wrote 1 EOF to "LTO-7" (/dev/nst0)
btape: btape.c:1177-0 Wrote 10000 blocks of 64412 bytes.
btape: btape.c:612-0 Wrote 1 EOF to "LTO-7" (/dev/nst0)
btape: btape.c:1219-0 Rewind OK.
29-Dec 11:19 btape JobId 0: Fatal error: block_util.c:425 Volume data
error at 0:0! Wanted ID: "BB02", got "". Buffer discarded.
btape: btape.c:1236-0 Read block 1 failed! ERR=block_util.c:425 Volume
data error at 0:0! Wanted ID: "BB02", got "". Buffer discarded.

[root@fs1 etc]# lsscsi -g
[11:0:1:0]   tape    IBM      ULTRIUM-HH7      H5B3  /dev/st0   /dev/sg3
[11:0:1:1]   mediumx BDT      FlexStor II      5.40  /dev/sch0  /dev/sg4

Autochanger {
  Name = Autochanger
  Device = LTO-7
  Changer Device = /dev/sg4
  Changer Command = "/etc/bacula/scripts/mtx-changer %c %o %S %a %d"
}

Device {
  Name = LTO-7
  Media Type = LTO-7
  Archive Device = /dev/nst0
  AutomaticMount = yes;
  AlwaysOpen = yes;
  RemovableMedia = yes;
  RandomAccess = no;
  Spool Directory = "/tmp"
  Maximum Spool Size = 10GB
  Maximum File Size = 10GB
  AutoChanger = yes
}

[1]
https://www.bacula.org/9.4.x-manuals/en/problems/Testing_Your_Tape_Drive_Wit.html#SECTION00431000000000000000