Several months ago, I got copy jobs set up and working. Sizes, counts, and retention settings were all identical to the corresponding primary pools when I started. After a while, I began seeing copy jobs waiting for appendable volumes. I began manually marking the oldest volume per pool for recycling, then I increased the maximum volume counts. Still I have copy jobs reporting no available volumes. This involves some systems but not others, even with systems that are effectively clones of each other.
Today I discovered that volumes in the problematic copy pools are being marked as Used before they have reached the Maximum Volume Jobs setting. Some volumes contain only one or two jobs, where I have the maximum set to six. I am running Bacula 7.4.4 on Debian 9. Any explanations or suggestions would be appreciated. Thanks, Brendan -- *Brendan E. Martin* | Systems Administrator II Department of Physics and Astronomy | Texas A&M University 4242 TAMU | College Station, Texas 77843-4242 979.845.7717 main | 979.845.2590 fax | bren...@physics.tamu.edu <mailto:bren...@physics.tamu.edu> http://physics.tamu.edu
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users